<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>International Journal of Radiation Research</title>
<title_fa>نشریه پرتو پژوه</title_fa>
<short_title>Int J Radiat Res</short_title>
<subject>Basic Sciences</subject>
<web_url>http://ijrr.com</web_url>
<journal_hbi_system_id>79</journal_hbi_system_id>
<journal_hbi_system_user>journal79</journal_hbi_system_user>
<journal_id_issn>2322-3243</journal_id_issn>
<journal_id_issn_online>2345-4229</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/ijrr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2019</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>17</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation 
</title>
	<subject_fa>Radiation Biology</subject_fa>
	<subject>Radiation Biology</subject>
	<content_type_fa>تحقيق بديع</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.&amp;nbsp; Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjacent organs, with the contralateral (opposite side) breast shielded. The shield was designed to have a simple (┓,┎) shape for ease of use in actual clinical settings, using lead, copper, bismuth, and barium sulphate (BaSO4) as materials for shield configuration. Results: The dosimetric data revealed that the highest absorbed dose was exhibited by the target filter combination of Rh/Rh, followed by W/Rh, W/Mo, Rh/Mo, Mo/Rh, and Mo/Mo. Additionally, the radiation dose was reduced by 54&amp;ndash;55%, with the average absorbed dose on the contralateral breast reduced from 0.655 to 0.359 mGy. All four shielding materials used in the experiments were analysed for the shielding effect. &amp;nbsp;Conclusion: This Using a shield during screening mammography would alleviate concerns about the mammography-induced risk of breast cancer and secondary effects.&amp;nbsp;&lt;/div&gt;
</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Mammography, Simulation, Shielding material, Contralateral dose</keyword>
	<start_page>127</start_page>
	<end_page>135</end_page>
	<web_url>http://ijrr.com/browse.php?a_code=A-10-1-765&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>D.Y. </first_name>
	<middle_name></middle_name>
	<last_name>Lee</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460013220</code>
	<orcid>7900319475328460013220</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Radiation Oncology, Dongnam Institute of Radiological &amp; Medical Sciences Cancer Center, 40, Jwadong-gil, Busan, Republic of Korea</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>J.S. </first_name>
	<middle_name></middle_name>
	<last_name>Lee</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>sonojinsoo@naver.com</email>
	<code>7900319475328460013221</code>
	<orcid>7900319475328460013221</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Radiology, Inje University Haeundae Paik Hospital, 875, Haeundae-ro, Haeundae-gu, Busan, Republic of Korea</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
