<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>International Journal of Radiation Research</title>
<title_fa>نشریه پرتو پژوه</title_fa>
<short_title>Int J Radiat Res</short_title>
<subject>Basic Sciences</subject>
<web_url>http://ijrr.com</web_url>
<journal_hbi_system_id>79</journal_hbi_system_id>
<journal_hbi_system_user>journal79</journal_hbi_system_user>
<journal_id_issn>2322-3243</journal_id_issn>
<journal_id_issn_online>2345-4229</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/ijrr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1402</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Effect of collimator scatter factors on dose calculation of different breast cancer cases in radiotherapy</title>
	<subject_fa>Radiation Biology</subject_fa>
	<subject>Radiation Biology</subject>
	<content_type_fa>تحقيق بديع</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;text-justify:newspaper&quot;&gt;&lt;span style=&quot;text-kashida-space:50%&quot;&gt;&lt;span style=&quot;line-height:119%&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;Background&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;The present study aims to estimate the effect of collimator, phantom and Multi-Leaf Collimator (MLC) scatters on dose calculation in different breast cancer cases using acrylic, brass build-up caps and acrylic mini-phantom in the measurements. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;Materials and Methods&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;Collimator scatter factors (Sc), phantom scatter factors (Sp) and MLC transmission factors for different field sizes ranging from 1 &amp;times; 1 cm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:5.9939pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt; to 40 &amp;times; 40 cm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:5.9939pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&amp;nbsp; for energies 6 MV and 15 MV&amp;nbsp; were measured using acrylic mini-phantom (PTW and local mini-phantom), acrylic build up cap and brass build up cap where the farmer ionization chamber was used as detector in this study and semiflex detector was used but only with small field sizes from 1 &amp;times; 1 cm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:5.9939pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&amp;nbsp; to 4 &amp;times; 4 cm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:5.9939pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt; and scatter effect on the dose calculation in different breast cancer cases was evaluated. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;Results&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;The results in this study show that there is no significant difference between MLC transmission factors using acrylic mini-phantom and brass build-up cap with energy 6 MV where the transmission factor value is 0.007 and 0.0071 with acrylic mini-phantom and brass build- up cap, respectively.&amp;nbsp; Also it is clear that brass build-up cap gives the highest collimator scatter factors results where collimator scatter factors start at value 0.963 at field size 4 &amp;times; 4 cm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:5.9939pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt; then increase gradually to end at point value 1.049 at field size 40 &amp;times; 40 cm&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:5.9939pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;. In breast cancer cases, there is sharp increase in organ at risk doses with brass build-up cap. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-style:italic&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;Conclusion&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;color:#1f497d&quot;&gt;&lt;span style=&quot;font-weight:bold&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;en-US&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;font-family:Calibri&quot;&gt;&lt;span style=&quot;language:en-US&quot;&gt;From this study it is evident that almost there is large variation between the acrylic build-up cap, acrylic mini-phantom and brass build-up cap where brass build-up achieve higher results in most measurements.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Collimator scatter factor, mini-phantom, build-up cap, brass, MLC transmission.</keyword>
	<start_page>553</start_page>
	<end_page>560</end_page>
	<web_url>http://ijrr.com/browse.php?a_code=A-10-1-1079&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>M.A. </first_name>
	<middle_name></middle_name>
	<last_name>Eid</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohamedahmed@gstd.sci.cu.edu.eg </email>
	<code>7900319475328460024378</code>
	<orcid>7900319475328460024378</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Radiotherapy Department, Nasser Institute, Cairo, Egypt</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H.S. </first_name>
	<middle_name></middle_name>
	<last_name>Mohammed</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460024379</code>
	<orcid>7900319475328460024379</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Biophysics Department, Faculty of Science, Cairo University, Egypt</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>A.M. </first_name>
	<middle_name></middle_name>
	<last_name>Abdelaal</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460024380</code>
	<orcid>7900319475328460024380</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Radiotherapy Department, Nasser Institute, Cairo, Egypt</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>S. </first_name>
	<middle_name></middle_name>
	<last_name>Taha</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460024381</code>
	<orcid>7900319475328460024381</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Biophysics Department, Faculty of Science, Cairo University, Egypt</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
