Department of Oncology, The Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Luzhou, China , 530018842@qq.com
Abstract: (446 Views)
Background:In thoracic tumor radiotherapy, tumor movement with respiration can affect dose distribution, potentially complicating the assessment of dose delivery to organs at risk (OAR). However, no standardized evaluation methods have been reported. We aimed to evaluate the dose–response effects caused by target movement and propose a more accurate method for assessing spinal cord dose in interstitial brachytherapy. Materials and Methods: Computed tomography (CT) data from 14 patients with lung cancer undergoing interstitial brachytherapy were used to design a distance-change model: f(d)=a×ebd. In this model, the distance (d) between the spinal cord and the clinical target volume (CTV) was defined, and f(d) represented spinal cord radiation dose parameters, including the maximum spinal cord dose (Dmax), dose to 1 cm³ (D1cc), dose to 0.1 cm³ (D0.1cc), and dose to 1% of the volume (D1%). Each parameter was fitted separately, assuming that the CTV exhibited simple harmonic oscillation. An experiment was designed to measure the effect of radiation source movement on point dose. Results: The coefficient of determination (R²) for the exponential fitting curves of all dose variables exceeded 0.90. Specifically, the R² value was 0.94 for Dmax and 0.95 for D1cc, D0.1cc, and D1%. The significance of f(d) was evaluated using the F-test, with p<0.05 considered statistically significant. The F-values for Dmax, D1cc, D0.1cc, and D1% were 2,362.63, 3,158.41, 2,705.33, and 2,604.93, respectively, all with p<0.01. Conclusion: Reliance on static CT images in radiotherapy planning systems may result in inaccurate spinal cord dose estimates.
1. Xiang L, Ren PR, Li HX, et al. (2023) Effect of 3-dimensional interstitial high-dose-rate brachytherapy with regional metastatic lymph node intensity-modulated radiation therapy in locally advanced peripheral non-small cell lung cancer: 5-year follow-up of a phase 2 clinical trial. Int J Radiat Oncol Biol Phys, 115: 347-355. [DOI:10.1016/j.ijrobp.2022.07.028]
2. Yaprak G, Doğan ÖY, Atasoy Ö, et al. (2025) The relationship between lung doses, dosimetric factors, survival, and radiation pneumonitis in lung cancer treated with volumetric-modulated arch therapy and helical tomotherapy. Int J Radiat Res, 23(3): 535-542. [DOI:10.61882/ijrr.23.3.4]
3. Huang Na, Peng Xi-Hao, Feng Xi, et al. (2021) Investigation and analysis of the current situation and demand of radiotherapy resources in western China in 2019. Chin J Cancer Prev Treat, 28(24): 1882-1887.
4. Zhang Q, Wang Y, Fang P (2019) Assessment and analysis for deployment appropriateness of medical linear accelerator at hospitals in China. Chin J Hosp Administr, 35(7): 566-570.
5. Stroom JC and Heijmen BJ (2002) Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 report. Radiother Oncol, 64(1): 75-83. [DOI:10.1016/S0167-8140(02)00140-8]
6. Yang B, Pang H, Liu X, et al. (2021) Influence of CTV movement on the maximal dose of spinal cord for patients with lung cancer undergoing interstitial brachytherapy. Chin J Cancer Prev Treat, 28: 934-943.
7. Breen SL, Craig T, Bayley A, et al. (2006) Spinal cord planning risk volumes for intensity-modulated radiation therapy of head-and-neck cancer. Int J Radiat Oncol Biol Phys, 64(1): 321-325. [DOI:10.1016/j.ijrobp.2005.08.038]
8. Yang B, Sun X, Pang H, et al. (2020) Determining whether multiple needles are necessary in interstitial brachytherapy for thoracic tumors: A dosimetry analysis. Indian J Cancer, 57(4): 437-442. [DOI:10.4103/ijc.IJC_693_18]
9. Das RK (1998) Icru 58 (dose and volume specification for reporting interstitial therapy), by international commission on radiation units and measurements. Med Phys, 25: 1225. [DOI:10.1118/1.598300]
10. Yang B, Sun X, Pang H, et al. (2017) Dosimetric analysis of rib interference of the CTV during interstitial brachytherapy of lung tumors. J Contemp Brachytherapy, 9(6): 566-571. [DOI:10.5114/jcb.2017.72359]
11. Fürweger C, Drexler C, Muacevic A, et al. (2014) Cyberknife robotic spinal radiosurgery in prone position: Dosimetric advantage due to posterior radiation access? J Appl Clin Med Phys, 15(4): 11-21. [DOI:10.1120/jacmp.v15i4.4427]
12. Ghia AJ, Guha-Thakurta N, Hess K, et al. (2018) Phase 1 study of spinal cord constraint relaxation with single session spine stereotactic radiosurgery in the primary management of patients with inoperable, previously unirradiated metastatic epidural spinal cord compression. Int J Radiat Oncol Biol Phys, 102(5): 1481-1488. [DOI:10.1016/j.ijrobp.2018.07.2023]
13. van der Kogel AJ (1993) Dose-volume effects in the spinal cord. Radiother Oncol, 29(2): 105-109. [DOI:10.1016/0167-8140(93)90234-Y]
14. Kirkpatrick JP, van der Kogel AJ, Schultheiss TE (2010) Radiation dose-volume effects in the spinal cord. Int J Radiat Oncol Biol Phys, 76(3): S42-S49. [DOI:10.1016/j.ijrobp.2009.04.095]
15. Tian X, Shen Z, Wang S, et al. (2024) Dosimetric comparison of different radial and longitudinal margins for tomotherapy in esophageal cancer. Int J Radiat Res, 22(2): 387-393. [DOI:10.61186/ijrr.22.2.387]
16. Donaldson HH, Davis DJ (2004) Description of charts showing the areas of the cross sections of the human spinal cord at the level of each spinal nerve. J Comp Neurol, 13(1): 19-40. [DOI:10.1002/cne.910130104]
17. Zhang KR, Lu SX, Zheng JZ (Year ????) Cross section area and volume of the spinal cord segments of Chinese. Acta Anat Sin, 11: 277-282.
18. Zhao KL, Liao Z, Bucci MK, et al. (2007) Evaluation of respiratory-induced target motion for esophageal tumors at the gastroesophageal junction. Radiother Oncol, 84(3): 283-289. [DOI:10.1016/j.radonc.2007.07.008]
19. Dieleman EM, Senan S, Vincent A, et al. (2007) Four-dimensional computed tomographic analysis of esophageal mobility during normal respiration. Int J Radiat Oncol Biol Phys, 67(3): 775-780. [DOI:10.1016/j.ijrobp.2006.09.054]
20. Yaremko BP, Guerrero TM, McAleer MF, et al. (2008) Determination of respiratory motion for distal esophagus cancer using four-dimensional computed tomography. Int J Radiat Oncol Biol Phys, 70(1): 145-153. [DOI:10.1016/j.ijrobp.2007.05.031]
21. van Sörnsen de Koste JR, Lagerwaard FJ, Nijssen-Visser MR, et al. (2003) Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans. Int J Radiat Oncol Biol Phys, 56(2): 348-354. [DOI:10.1016/S0360-3016(02)04467-X]
22. Michalski D, Sontag M, Li F, et al. (2008) Four-dimensional computed tomography-based interfractional reproducibility study of lung tumor intrafractional motion. Int J Radiat Oncol Biol Phys, 71(3): 714-724. [DOI:10.1016/j.ijrobp.2007.10.038]
23. Sadeghi-Naini A, Shirzadi Z, Samani A (2012) Towards modeling tumor motion in the deflated lung for minimally invasive ablative procedures. Comput Aided Surg, 17(5): 211-220. [DOI:10.3109/10929088.2012.708788]
24. Silva SR, Surucu M, Steber J, et al. (2017) Clinical application of a hybrid rapidarc radiotherapy technique for locally advanced lung cancer. Technol Cancer Res Treat, 16(2): 224-230. [DOI:10.1177/1533034616670273]
25. Ahmed N, Venkataraman S, Johnson K, et al. (2017) Does motion assessment with 4-dimensional computed tomographic imaging for non-small cell lung cancer radiotherapy improve target volume coverage? Clin Med Insights Oncol, 11: 1179554917698461. [DOI:10.1177/1179554917698461]
26. Chan MK, Kwong DL, Tam E, et al. (2013) Quantifying variability of intrafractional target motion in stereotactic body radiotherapy for lung cancers. J Appl Clin Med Phys, 14(5): 140-152. [DOI:10.1120/jacmp.v14i5.4319]
27. Plathow C, Ley S, Fink C, et al (2004) Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. Int J Radiat Oncol Biol Phys, 59(4): 952-959. [DOI:10.1016/j.ijrobp.2003.12.035]
28. van Sörnsen de Koste JR, Lagerwaard FJ, Nijssen-Visser MR, et al. (2003) Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans. Int J Radiat Oncol Biol Phys, 56(2): 348-354. [DOI:10.1016/S0360-3016(02)04467-X]
29. Michalski D, Sontag M, Li F, et al. (2008) Four-dimensional computed tomography-based interfractional reproducibility study of lung tumor intrafractional motion. Int J Radiat Oncol Biol Phys, 71(3): 714-724. [DOI:10.1016/j.ijrobp.2007.10.038]
30. Rashid A, Pinkawa M, Haddad H, et al. (2021) Interstitial single fraction brachytherapy for malignant pulmonary tumours. Strahlenther Onkol, 197(5): 416-422. [DOI:10.1007/s00066-021-01758-5]
31. Borot de Battisti M, Denis de Senneville B, Hautvast G, et al. (2017) A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy. Phys Med Biol, 62(10): 4031-4045. [DOI:10.1088/1361-6560/aa664b]
32. Hashimoto M, Ito Y, Tanaka Y, et al. (2023) Four-dimensional dose reconstruction system for lung cancer VMAT treatment: a 4D phantom study. Int J Radiat Res, 21(3): 469-474. [DOI:10.61186/ijrr.21.3.469]
33. Tanabe Y, Deguchi T, Kiritani M, et al. (2024) Evaluation of statistical prediction model fitting by combining fiducial markers and lung volume for stereotactic body radiotherapy. Int J Radiat Res, 22(1): 17-22. [DOI:10.61186/ijrr.22.1.17]
Zhang G, Zhang J, Huang Z, Han Y, Yang B. Impact of thoracic tumor motion on spinal cord radiation dose parameters in interstitial brachytherapy. Int J Radiat Res 2026; 24 (4) :1143-1149 URL: http://ijrr.com/article-1-7394-en.html