Department of Radiation Oncology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India , jjyothi.nagesh@manipal.edu
Abstract: (471 Views)
Background:The purpose is to identify the standard minimum segment width [MSW] in terms of planning outcomes of Volumetric modulated arc therapy [VMAT] in patients with Head and Neck Carcinoma [HNC]. Material and Methods: A retrospective analysis was conducted using planning computed tomography scans from 15 patients diagnosed with head and neck carcinoma. Four separate VMAT plans, utilizing MSW of 0.5 cm, 1.0 cm, 1.5 cm, and 2.0 cm, were created in the Monaco Treatment Planning system [TPS]version 5.11.03. Target volume and critical structures were optimized with the same criteria. The comparison focused on Conformity Index [CI], Homogeneity Index [HI], target volume coverage, dose to Organs at risk [OARs], and total Monitor units (MUs). Data analysis was performed using Jamovi software. At p<0.05, statistical significance was established. Results: MSW of 1.0 cm plans showed significantly enhanced planning target volume [PTV] coverage [p=0.021], fewer monitor units [p=0.03], and an optimal combination of Conformity [CI = 0.816±0.214] and Homogeneity [HI = 1.065±0.017]. Furthermore, the spinal cord received a substantially lower maximum dose in plans created with 0.5 cm and 1.0 cm MSWs compared to those with wider segment widths [p=0.017]. Conclusions: Among the configurations tested, the 1.0 cm MSW offered the most favorable balance between precise target coverage, organ-at-risk sparing, and overall treatment delivery efficiency for head and neck cancer using VMAT planning.
1. Kubo K, Murakami Y, Imano N, Takeuchi Y, Nishibuchi I, Kimura T, et al. (2020) A single institution's experience of definitive radiotherapy using volumetric-modulated Arc therapy for hypopharyngeal cancers. Anticancer Res, 40(7): 4183-90. [DOI:10.21873/anticanres.14418]
2. Bray F, Ferlay J, Soerjomataram I, Siegel RL, Torre LA, Jemal A (2018) Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin, 68(6): 394-424. [DOI:10.3322/caac.21492]
3. Rettig EM and D'Souza G (2015) Epidemiology of head and neck cancer. Surg Oncol Clin N Am, 24(3): 379-96. [DOI:10.1016/j.soc.2015.03.001]
4. Ayman N, Abdelaal A, Amer HH, Mohammed HS (2025) Impact of slice thickness and grid size on dose calculation in intensity modulated and volumetric-modulated Arc radiotherapy in head and neck cancer. International Journal of Radiation Research, 23(2): 263-70. [DOI:10.61186/ijrr.23.2.1]
5. Mazonakis M, Kachris S, Damilakis J (2021) VMAT for prostate cancer with 6-MV and 10-MV photons: Impact of beam energy on treatment plan quality and model-based secondary cancer risk estimates. Mol Clin Oncol, 14(5): 89. [DOI:10.3892/mco.2021.2251]
6. Rashid A, Ahmed Z, Memom MA, Hashim ASM (2021) Volumetric modulated arc therapy (VMAT): A modern radiotherapy technique - A single institutional experience. Pak J Med Sci, 37(2): 355-61. [DOI:10.12669/pjms.37.2.2647]
7. Zeng IJ, Lu L, Liu XY, Hu CR, Hong J, Guo FB, et al. (2025) Dosimetric response of the Delta4 system for small fields and the impact on dose verification accuracy. International Journal of Radiation Research, 23(3): 677-82. [DOI:10.61882/ijrr.23.3.23]
8. Sardari D, Saeedzadeh E, Karimkhani L, Mahdavi SR (2025) Evaluation of Monaco dose calculation errors for out-of-field regions in intensity modulated radiotherapy of nasopharyngeal cancer. International Journal of Radiation Research, 23(1): 225-32. [DOI:10.61186/ijrr.23.1.225]
9. Jain N, Kumar A, Kumar A (2024) Investigating the influence of minimum segment width in volumetric-modulated arc planning of prostate cancer. Turk Onkoloji Dergisi, 39(1): 84-91. [DOI:10.5505/tjo.2023.4137]
10. Nithiyanantham K, Kadirampatti Mani G, Subramani V, Karukkupalayam PK, Uthiran M, Vellengiri S, et al. (2014) Influence of segment width on plan quality for volumetric modulated arc based stereotactic body radiotherapy. Reports of Practical Oncology & Radiotherapy, 19(5): 287-95. [DOI:10.1016/j.rpor.2014.03.003]
11. Wang Y, Chen L, Zhu F, Guo W, Zhang D, Sun W (2018) A study of minimum segment width parameter on VMAT plan quality, delivery accuracy, and efficiency for cervical cancer using Monaco TPS. J Appl Clin Med Phys, 19(5): 609-15. [DOI:10.1002/acm2.12422]
12. Yoosuf AM, Ahmad MB, AlShehri S, Alhadab A, Alqathami M (2021) Investigation of optimum minimum segment width on VMAT plan quality and deliverability: A comprehensive dosimetric and clinical evaluation using DVH analysis. J Appl Clin Med Phys, 22(11): 29-40. [DOI:10.1002/acm2.13417]
13. Kaur SP, Shivanjli, Oinam AS, Shahi JS, Srinivasan, Kumari R, et al. (2025) Effect of minimum segment width on SRT/SBRT volumetric Arc therapy plans for flattening filter free beams. Asian Pacific Journal of Cancer Biology, 10(2): 309-13. [DOI:10.31557/apjcb.2025.10.2.309-313]
14. Hong J, Han JH, Luo HL, Song YQ (2021) Optimization of minimum segment width parameter in the intensity-modulated radiotherapy plan for esophageal cancer. Int J Gen Med, 14: 9913-21. [DOI:10.2147/IJGM.S336269]
15. Thimothy G, Joan M, Vijay A (2025) Enhancing treatment efficiency: investigating the optimal segment width in volumetric modulated arc therapy for prostate cancer management. J Med Phys, 50(2): 312-9. [DOI:10.4103/jmp.jmp_9_25]
16. Kataria T, Sharma K, Subramani V, Karrthick K, Bisht S (2012) Homogeneity index: An objective tool for assessment of conformal radiation treatments. J Med Phys, 37(4): 207. [DOI:10.4103/0971-6203.103606]
Malar L, Nagesh J, Nair S, Shambhavi C, Lewis S, Singh A, et al . Assessment of the impact of minimum segment width on volumetric modulated Arc therapy planning for head and neck cancer. Int J Radiat Res 2026; 24 (4) :1151-1155 URL: http://ijrr.com/article-1-7395-en.html